Representative Image

DOSTMANN PDF Data Logger LOG210 TC with Display for Temperature and Humidity, 2x External (Type K)

Brand:Dostmann

Specifications

HS Code #
90258040
Depth
20 mm
Dimensions (WxDxH)
42 x 20 x 91.5 mm
Height
91.5 mm
Max. measuring cycle
24 h
Max. relative humidity
100 %
Max. temp. (external)
1370 °C
Max. temperature
70 °C
Measuring cycle
10 sec ... 24 h
Min. measuring cycle
10 sec
Min. relative humidity
0 %

₹28,422.66

Inc. GST

Available soon

Product description

The DOSTMANN PDF Data Logger LOG210 TC is an advanced device designed to monitor both temperature and humidity, featuring a display for real-time data visualization. Equipped with two external Type K thermocouple inputs and a motion sensor for shock recording, this logger provides precise environmental monitoring ideal for industrial, laboratory, and transport applications. It offers a freely adjustable recording interval from 10 seconds to 24 hours, min and max values resettable on the display, and a time marking function ("Time Marker") during data recording. The device supports automatic PDF output via USB without requiring software or driver installation. Status and alarm LEDs with buzzer alerts ensure reliable notifications, and the display can be switched off to conserve power. Battery life exceeds 4 years at intervals greater than 15 minutes.

Key Features:

  • Brand: DOSTMANN
  • Display: Integrated display for easy viewing of temperature and humidity readings with min/max reset
  • Temperature Inputs: 2x external Type K thermocouple inputs (1 m length)
  • Humidity Measurement: Accurate humidity tracking for complete environmental monitoring (sensor sold separately)
  • Motion Sensor: Detects shocks and movement during recording
  • Recording Interval: Freely adjustable from 10 seconds to 24 hours
  • Time Marking Function: "Time Marker" for marking events during data recording
  • Data Output: Automatic PDF generation via USB; device usable without software or driver installation
  • No Driver Installation Needed
  • USB Interface: For easy data transfer
  • Memory Capacity: Stores approximately 60,000 measurements
  • Alarm System: Status and alarm LEDs with buzzer
  • Power: Battery life greater than 4 years at intervals over 15 minutes
  • Can Be Switched: Can be switched off to save power
  • Software: Available for free download on the manufacturer's website
  • Applications: Ideal for industrial, laboratory, and transport environments requiring precise temperature and humidity logging

Scope of Supply:

  • Data logger
  • 2 thermocouples type K (1 m length)
  • Wall mount
  • Battery
  • USB cover
  • Screws and dowels

Temperature and humidity sensors are available separately.

The DOSTMANN PDF Data Logger LOG210 TC offers comprehensive environmental monitoring with dual external temperature inputs and humidity tracking, making it an essential tool for a wide range of applications.

Accessories

Sensor cable extension

ProductDescriptionUNSPSCMfr#Part#AvailabilityPrice
Sensor cable extension, 2 m411165005090-00716.317 624₹2,750.58

Thermocouple, thermocouple Type K, fibre glass insulated

ProductType of probeMax. temperatureMfr#Part#AvailabilityPrice
Type K400 °C6010-00587.920 403₹5,632.14

Frequently asked questions

It is an advanced device designed to monitor both temperature and humidity, featuring a display for real-time data visualization. Equipped with two external Type K thermocouple inputs and a motion sensor for shock recording, this logger provides precise environmental monitoring ideal for industrial, laboratory, and transport applications. It offers a freely adjustable recording interval from 10 seconds to 24 hours, min and max values resettable on the display, and a time marking function ("Time Marker") during data recording. The device supports automatic PDF output via USB without requiring software or driver installation. Status and alarm LEDs with buzzer alerts ensure reliable notifications, and the display can be switched off to conserve power. Battery life exceeds 4 years at intervals greater than 15 minutes.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story