Specifications

HS Code #
90278930
Accuracy temperature
±0.1 °C
Accuracy temperature
0.1 °C
Battery/ rechargeable battery
4 x 1.5 V, AA
Intake capacity
0.01 ... 50.00 mg/l (ppm)
Concentration accuracy
±0.1 mg/l (0 ... 8 mg/l)/±0.2 mg/l (8 ... 20 mg/l)/±10 % (20 ... 50 mg/l)
Concentration resolution
0.01 mg/l (ppm)
Depth
35 mm
Designation ANSI
AA
Dimensions (WxDxH)
70 x 35 x 222 mm
Height
222 mm

₹310,946.52

Inc. GST

Available soon

Product description

The Mettler-Toledo Seven2Go RDO S9 BOD Kit Base Unit combines advanced dissolved oxygen measurement technology with a complete set of accessories for Biological Oxygen Demand (BOD) testing. Featuring the InLab OptiOx sensor, this kit provides fast, accurate, and reliable oxygen level readings essential for environmental monitoring and wastewater analysis. Included calibration bottles, zero oxygen tablets, and a durable UGO carrying case make it a versatile, ready-to-use solution for field and laboratory applications.

Key Features:

  • Brand: Mettler-Toledo
  • Model: Seven2Go RDO S9 BOD Kit Base Unit
  • Sensor: InLab OptiOx for precise dissolved oxygen measurement
  • Accessories: Calibration bottles and zero oxygen tablets included
  • Portability: Comes with rugged UGO carrying case for easy transport
  • Applications: Ideal for BOD testing, environmental monitoring, and wastewater analysis
  • Connection: Portable professional model for dissolved oxygen measurement
  • Ease Of Use: New intuitive menu structure with fast and easy T-Pad navigation
  • Safety Details: Robust design with IP67 protection for harsh environments
  • Sensor Management: Intelligent Sensor Management (ISM) functionality reduces errors
  • Display: Sunlight-proof screen ensures readability even in direct sunlight
  • Status Indicator: StatusLight for quick visual measurement readiness confirmation
  • Construction Material: Supports 12 languages with full sentence display
  • Calibration Function: Up to 2 calibration points and choice of 2 predefined oxygen standards
  • Endpoint Detection: Automatic, manual, and time-dependent endpoint recording
  • Connectivity: Data memory for 2000 GLP data points with weatherproof Micro-USB data export
  • Power: 4 x 1.5 V AA or 1.3 V NiMH accumulators

Scope of Supply:

  • S9-Meter: Instrument, LabX direct pH, USB cable, electrode clip, base accessory, operating instructions, quick guide, test certificate, declaration of conformity, batteries
  • S9-Standard kit: As S9-Meter plus InLab OptiOx, zero oxygen tablets
  • S9-Field kit: As S9-Standard kit plus calibration bottles, UGO carrying case, InLab OptiOx with protective guard
  • S9-BOD kit: As S9-Field kit plus InLab OptiOx (without protective guard), BOD adapter, BOD application note

This kit offers a comprehensive, accurate, and portable solution for professionals performing dissolved oxygen and BOD measurements.

Frequently asked questions

It combines advanced dissolved oxygen measurement technology with a complete set of accessories for Biological Oxygen Demand (BOD) testing. Featuring the InLab OptiOx sensor, this kit provides fast, accurate, and reliable oxygen level readings essential for environmental monitoring and wastewater analysis. Included calibration bottles, zero oxygen tablets, and a durable UGO carrying case make it a versatile, ready-to-use solution for field and laboratory applications.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story