Cole-Parmer Program Digital Melting Point Apparatus MP-250DPR, Beginning/Ending Recording, 100–240 VAC

Specifications

HS Code #
90278100
Depth
355 mm
Ø capillaries
2 mm
Dimensions (WxDxH)
200 x 355 x 80 mm
Power supply frequency
50/60 Hz
Heating rate
0,2 ... 10 °C/min
Height
80 mm
Interfaces
RS232, USB
Max. no. of sample positions
3
Max. temperature
400 °C
Max. voltage
240 V

₹593,601.36

Inc. GST

Available soon

Product description

The Cole-Parmer Programmable Digital Melting Point Apparatus MP-250DPR offers advanced functionality for accurate and repeatable melting point determination, including the ability to record both the beginning and end of the melt. Designed for precision and ease of use, this instrument supports a broad voltage range of 100–240 VAC at 50/60 Hz, making it ideal for international lab environments. With fully programmable features, adjustable ramp rates, and data storage capabilities, it’s well-suited for quality control, academic, and research laboratories requiring reliable thermal analysis.

Key Features:

  • Brand: Cole-Parmer
  • Model: MP-250DPR
  • Functionality: Records both start and end of melting point for accurate results
  • Programmability: Fully programmable for routine and complex analysis
  • Ramp Rate: Individually adjustable for customizable heating profiles
  • Batch Memory: Stores up to 500 determinations with date, time, and batch number
  • Interfaces: RS232 for printer connection (printer sold separately) and USB for PC data transfer
  • Temporary Memory: Stores start and end points for up to three temperatures
  • Voltage: 100–240 VAC, 50/60 Hz for global use
  • Application: Ideal for research, academic, and quality assurance laboratories

Scope of Supply:

  • Melting point apparatus
  • Lens hood
  • Power supply with EU, UK, and US plug
  • 100 melting point tubes

Note: Please order the printer separately for RS232 connectivity.

The Cole-Parmer MP-250DPR is an essential laboratory instrument for automated and precise melting point analysis, offering programmable control, reliable documentation, and flexible compatibility with laboratory data systems.

Accessories

Melting point tubes Electrothermal

ProductLengthExt. ØMfr#Part#AvailabilityPrice
100 mm1.5 mm03010-679.830 463₹8,382.72
100 mm2.0 mm03010-684.683 696₹148,793.28

More items to explore

Electrothermal Melting point apparatus MP-250D-F

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
MP-250D-FMains connection03010-519.830 441₹367,267.92

Electrothermal Melting point apparatus MP-250D-P

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
MP-250D-PMains connection03010-419.830 442₹436,687.32

Frequently asked questions

It offers advanced functionality for accurate and repeatable melting point determination, including the ability to record both the beginning and end of the melt. Designed for precision and ease of use, this instrument supports a broad voltage range of 100–240 VAC at 50/60 Hz, making it ideal for international lab environments. With fully programmable features, adjustable ramp rates, and data storage capabilities, it’s well-suited for quality control, academic, and research laboratories requiring reliable thermal analysis.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story