Representative Image

KNF LABOPORT Diaphragm Vacuum Pump N 96

Brand:KNF

Power supply frequency

Max. voltage

Plug type

Power supply

Type

Specifications

Compare models
HS Code #
84141089
Connection pressure side
ID 6 mm
Connection suction side
ID 6 mm
Depth
156 mm
Dimensions (WxDxH)
75 x 156 x 119 mm
Flow rate
7 l/min
Power supply frequency
50/60 Hz
Height
119 mm
Material media contact
PPS/PTFE-coated/FKM
Max. voltage
240 V
Min. voltage
100 V

₹119,584.74

Inc. GST

Supplier Stock: 19
Delivery: 2-4 weeks

Product description

The KNF LABOPORT Diaphragm Vacuum Pump N 96, 0.30 To 0.42 m³/h, Less Than 130 mbar Absolute, IP 40, With EU/UK/CH Plug combines a high flow rate with a very compact design for laboratory vacuum applications. With manual rotational speed control, this pump operates quietly and efficiently while allowing adjustment to suit filtration, SPE, and liquid aspiration workflows.

Key Features:

  • Brand: KNF
  • Product Type: Diaphragm vacuum pump
  • Range: LABOPORT
  • Model: N 96
  • Flow Rate: 0.30 to 0.42 m³/h
  • Ultimate Vacuum: Less than 130 mbar Absolute
  • Protection Rating: IP 40
  • Plug Type: With EU/UK/CH plug
  • Control: Manual rotational speed control with adjustable flow rate
  • Diaphragm: PTFE-coated diaphragm for use with aggressive and corrosive gases and vapours
  • Application: Suitable for filtration, SPE, and liquid aspiration using vacuum
  • Design: Very small footprint with easy-to-clean surface

This KNF LABOPORT diaphragm vacuum pump is suitable for laboratories requiring a compact, energy efficient, and manually adjustable vacuum pump for routine vacuum applications.

Accessories

Hydrophobic pump protection filter for Diaphragm vacuum pumps and pump systems LABOPORT® / LABOBASE®

ProductForUNSPSCMfr#Part#AvailabilityPrice
N 96, N 816.3 KT.18, N 816.1.2 KT.18, N 938.50 KT.18, N 820 G, N 840 G401515023321956.319 067₹12,443.10

Compare similar models

LABOPORT® Diaphragm Vacuum Pump N 96 0.30-0,42 m³/h, <130 mbar abs. IP 40, with EU-/UK-/CH-plug
In stock
KNF LABOPORT Diaphragm Vacuum Pump N 96

₹119,584.74

Inc. GST

Manufacturer P/N

322806/000000

Part Number

4.672 374

Manufacturer

KNF

Power supply frequency

50/60 Hz

LABOPORT® Diaphragm Vacuum Pump U N96 US-Plug - 115V/60HZ
Available soon
KNF LABOPORT Diaphragm Vacuum Pump U N96 US-Plug - 115V/60HZ

₹135,826.26

Inc. GST

Manufacturer P/N

U322806/000000

Part Number

4.686 731

Manufacturer

KNF

Power supply frequency

60 Hz

More items to explore

Diaphragm vacuum pumps LABOPORT® N 820 G / N 840 G, chemically-resistant

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EU/UK/CHN 820 G317121/3134524.672 375In stock₹350,895.42
EU/UK/CHN 840 G317123/3159944.672 376₹386,391.00
USU N 840 GU317123/3159954.686 738₹672,582.30
USU N 820 GU317121/3134534.686 739₹498,378.90

Frequently asked questions

It combines a high flow rate with a very compact design for laboratory vacuum applications. With manual rotational speed control, this pump operates quietly and efficiently while allowing adjustment to suit filtration, SPE, and liquid aspiration workflows.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story