Representative Image

OHAUS Centrifuge Multi FC5706P+R78 (Rotor Angle 6 x 50 mL RB/FA), 100-230 V

Brand:OHAUS

Specifications

Depth
540 mm
Dimensions (WxDxH)
323 x 540 x 365 mm
Power supply frequency
50/60 Hz
Height
365 mm
Max. rcf
4427 x g
Max. speed
6000 1/min
Max. voltage
230 V
Min. speed
200 1/min
Min. voltage
100 V
Noise level
56 db(A)

₹371,983.20

Inc. GST

Available soon

Product description

The Ohaus Centrifuge Multi FC5706P+R78 (Rotor Angle 6 ×, 50 mL RB/FA) 100-230V is designed for laboratory sample separation and centrifugation. Rotor Angle 6 x 50 ml RB/FA ID.

Key Features:

  • Brand: Ohaus
  • Product Type: Centrifuge Multi
  • Model: FC5706P+R78 Rotor Angle 6 ×
  • Capacity: 50 mL, 50 ml
  • Voltage: 100-230V
  • Application: laboratory sample separation and centrifugation

This Ohaus Centrifuge Multi is suitable for users needing reliable performance for laboratory sample separation and centrifugation.



Frequently Asked Questions

1. What is the Ohaus Centrifuge Multi FC5706P+R78 100-230V used for?

The FC5706P+R78 Rotor Angle 6 × is designed for laboratory sample separation and centrifugation. This centrifuge multi format supports routine laboratory work in that application.

2. What are the main specifications of the FC5706P+R78 Rotor Angle 6 ×?

The main specifications of the FC5706P+R78 Rotor Angle 6 × are that the capacity is 50 mL, 50 ml. These are the main selection points to compare with the requirements of the laboratory task.

3. Is the FC5706P+R78 Rotor Angle 6 × suitable for laboratory sample separation and centrifugation?

Yes. The FC5706P+R78 Rotor Angle 6 × is suitable for laboratory sample separation and centrifugation. The product is designed specifically for that type of work when its stated format and operating characteristics match the laboratory requirement.

4. What power requirement does the FC5706P+R78 Rotor Angle 6 × have?

The FC5706P+R78 Rotor Angle 6 × has a voltage specification of 100-230V. This should be matched with the available laboratory power setup.

Accessories

Fixed angle rotors for Centrifuge Frontier™ 5000 Multi

ProductTypeType of lidMfr#Part#AvailabilityPrice
R-A6x50/6MWithout301308784.661 537In stock₹121,418.46
R-A12x15/6MWithout301308774.661 536₹97,056.18

Swing-out rotor R-S6X5/4M for centrifuges Frontier™ 5000 Multi

ProductTypeFor devicesMfr#Part#AvailabilityPrice
R-S6X5/4MFC5706301308804.661 558₹114,738.48

More items to explore

Centrifuges Frontier™ 5000 Multi FC5706P, without rotor

ProductTypeRated capacityMfr#Part#AvailabilityPrice
FC5706P70 W310607784.713 494₹299,682.24

Centrifuges Frontier™ 5000 Multi FC5706P, with rotor angle R77

ProductTypeRated capacityMfr#Part#AvailabilityPrice
FC5706P+R7770 W310607794.713 495₹331,117.44

Frequently asked questions

The FC5706P+R78 Rotor Angle 6 × is designed for laboratory sample separation and centrifugation. This centrifuge multi format supports routine laboratory work in that application.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

₹371,983.20

Inc. GST