Representative Image

Bohlender Globe Stirring Couplings, POM Wave Adapter Ø 8 and 10 mm

Brand:Bohlender

Chuck adapter

Length

Opening for stirrer shaft

Specifications

Compare models
HS Code #
39269097
Axis/ angle offset
+10 mm
Chuck adapter
10 mm
Length
190 mm
Material
POM
Max. temperature
110 °C
Min. temperature
-20 °C
Opening for stirrer shaft
Ø 8 mm
Temperature
-20 ... 110 °C
UNSPSC
41103816

₹35,495.58

Inc. GST

Available soon

Product description

The Bohlender Globe Stirring Couplings, POM Wave Adapter Ø 8 and 10 mm are precision-engineered connectors designed to compensate for misalignments between stirrer shafts and drives. Manufactured from high-strength POM plastic, these couplings offer excellent mechanical properties, ensuring reliable and efficient power transmission in laboratory stirring applications.

Key Features:

  • Brand: Bohlender
  • Material: High-strength POM plastic for durability and chemical resistance
  • Opening for Stirrer Shaft: Ø 8 and 10 mm
  • Chuck Adapter Diameter: Ø 10 mm
  • Overall Length: 190 mm
  • Power Transmission: Up to 300 Ncm
  • Maximum Speed: Up to 1,200 rpm
  • Maximum Axial Misalignment: 10 mm
  • Temperature Range: -20°C to +110°C
  • Rotation: Suitable for both left and right-handed rotation
  • Assembly: Simple screw joint with clamp rings
  • Pivot Length: 90 mm (can be shortened by the user)
  • Applications: Ideal for balancing misalignment of axes between agitator and stirrer shaft; suitable for glass, metal, or PTFE stirrer shafts
  • Packaging: Sold individually

These couplings are essential for laboratories requiring precise and reliable connections in various research and analytical settings.

Compare similar models

Globe stirring couplings, POM wave adapter Ø 8 and 10 mm

Manufacturer P/N

C 398-12

Part Number

7.632 676

Manufacturer

Bohlender

Axis/ angle offset

+10 mm

Globe Stirrer Coupling, POM wave absorption Ø 6,5 and 10 mm

Manufacturer P/N

C 398-08

Part Number

6.240 637

Manufacturer

Bohlender

Axis/ angle offset

+10 mm

Globe stirrer coupling, POM wave adapter GL10 and 10 mm

Manufacturer P/N

C 393-12

Part Number

9.197 202

Manufacturer

Bohlender

Axis/ angle offset

-

Globus stirring coupler, POM for 6 mm internal square

Manufacturer P/N

C 399-12

Part Number

6.231 539

Manufacturer

Bohlender

Axis/ angle offset

-

Globus agitator couplings L 190 mm; Ø 8 + 10 mm Top mounting Ø 8 mm

Manufacturer P/N

C 394-03

Part Number

6.275 615

Manufacturer

Bohlender

Axis/ angle offset

+10 mm

Globe Stirrer Coupling, POM wave absorption Ø 4 mm

Manufacturer P/N

C 398-04

Part Number

6.272 999

Manufacturer

Bohlender

Axis/ angle offset

-

Globus agitator couplings L 190 mm; Ø 4 mm Top mounting Ø 8 mm

Manufacturer P/N

C 394-01

Part Number

4.670 726

Manufacturer

Bohlender

Axis/ angle offset

-

Globus agitator couplings L 190 mm; Ø 6,5 + 10 mm Top mounting Ø 8 mm

Manufacturer P/N

C 394-02

Part Number

4.667 597

Manufacturer

Bohlender

Axis/ angle offset

+10 mm

Frequently asked questions

It are precision-engineered connectors designed to compensate for misalignments between stirrer shafts and drives. Manufactured from high-strength POM plastic, these couplings offer excellent mechanical properties, ensuring reliable and efficient power transmission in laboratory stirring applications.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story