Amperage

Ext. dim. (WxDxH)

Ext. width

Int. Dim. (WxDxH)

Int. width

Power supply

Rated capacity

Type

Weight

Specifications

Compare models
Amperage
0.6 A
Depth int.
651 mm
Ext. dim. (WxDxH)
1,140 x 700 x 1,125 mm
Ext. depth
700 mm
Ext. height
1125 mm
Ext. width
1140 mm
Power supply frequency
50 Hz
Height int.
855 mm
Int. Dim. (WxDxH)
1,116 x 651 x 855 mm
Int. width
1116 mm

₹743,573.46

Inc. GST

Available soon

Product description

The Esco Ascent Opti Fume Hood SPD-4B1, 4 ft/1.2 m, 6 mm/0.2" Acrylic Back Panel, Hinged Front Panel, 220-240 VAC, 50 Hz is designed as a compact, energy-saving ductless fume hood for laboratory applications. This fume hood supports safe operation with an average inflow air velocity of 0.5 m/s, easy filter change, Sentinel microprocessor control, fluorescent lighting, acrylic panels and a stainless steel spill-retaining work top.

Key Features:

  • Brand: Esco
  • Product Type: Ductless fume hood
  • Model: Ascent Opti SPD-4B1
  • Size: 4 ft/1.2 m
  • Back Panel: 6 mm/0.2" acrylic back panel
  • Front Panel: Hinged front panel
  • Power Supply: 220-240 VAC, 50 Hz
  • Standard: Independently tested and complies with AFNOR NFX 15-211
  • Air Velocity: Average inflow air velocity of 0.5 m/s
  • Controller: Sentinel microprocessor with LCD display, air velocity alarm and 24-hour clock
  • Lighting: Fluorescent lighting for work zone illumination
  • Design: Sloped acrylic front window with transparent back wall for SPD-4B1
  • Side Walls: Acrylic side walls
  • Coating: ISOCIDE™ antimicrobial coating on all painted surfaces
  • Work Top: Stainless steel spill-retaining work top
  • Ports: Sampling port and pass-through ports in the back wall
  • Pre-Filter: Polyester fibre pre-filter with EU3 rating included
  • Assembly: Delivered unassembled, with on-site assembly possible in 60 minutes without special tools
  • Options On Request: Support stands and installation
  • Filter Requirement: Main filters must be ordered separately for operation

This Esco Ascent Opti fume hood is suitable for laboratories requiring a compact ductless hood with acrylic panels, simple filter access and reliable airflow monitoring.

Compare similar models

Ascent® Opti fume hood SPD-4B1 4ft/1.2m, 6 mm/0.2" acrylic back panel Hinged front panel, 220-240 VAC, 50 Hz

Manufacturer P/N

2040108

Part Number

4.676 174

Manufacturer

Esco

Amperage

0.6 A

Ascent® Opti Laboratory fume hood SPD-3A1 circulation air, 0.9m

Manufacturer P/N

2040099

Part Number

4.658 853

Manufacturer

Esco

Amperage

0.5 A

Ascent® Opti Laboratory fume hood SPD-4A1 circulation air, 1.2m Two main filter are needed in addition

Manufacturer P/N

2040105

Part Number

4.658 854

Manufacturer

Esco

Amperage

0.6 A

Ascent® Opti fume hood SPD-3B1 3ft/0.9m, 6 mm/0.2" acrylic back panel Hinged front panel, 220-240 VAC, 50 Hz

Manufacturer P/N

2040102

Part Number

4.676 173

Manufacturer

Esco

Amperage

0.5 A

Frequently asked questions

It is designed as a compact, energy-saving ductless fume hood for laboratory applications. This fume hood supports safe operation with an average inflow air velocity of 0.5 m/s, easy filter change, Sentinel microprocessor control, fluorescent lighting, acrylic panels and a stainless steel spill-retaining work top.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

₹743,573.46

Inc. GST