Representative Image

IKA Overhead Stirrer EUROSTAR 200 Control S 2, 0/6 - 2,000 min-1

Brand:IKA

Plug type

Type

Specifications

Compare models
HS Code #
84798200
Clamping range
0.5 ... 10 mm
Depth
231 mm
Dimensions (WxDxH)
91 x 231 x 297 mm
Display
Digital
Power supply frequency
50/60 Hz
Height
297 mm
IP code
IP 40
Max. clamping width
10 mm
Max. speed
2000 1/min
Max. stirring capacity
100 l

₹901,142.40

Inc. GST

Available soon

Product description

The IKA Overhead Stirrer EUROSTAR 200 Control S 2, 0/6 - 2,000 min-1, Without Accessories, With UK Plug is an extremely powerful laboratory stirrer designed for highly viscous applications and quantities up to 100 l (H2O). It features a removable wireless controller, digital TFT display, automatic speed adjustment, and constant speed control even when sample viscosity changes.

Key Features:

  • Brand: IKA
  • Product Type: Overhead stirrer
  • Model: EUROSTAR 200 Control S 2
  • Speed Range: 0/6 to 2,000 rpm across two speed ranges
  • Capacity: Suitable for quantities up to 100 l (H2O)
  • Plug Type: UK plug
  • Accessories: Without accessories
  • Controller: Removable wireless controller
  • Display: Multilingual digital TFT display
  • Interfaces: RS 232 and USB interface for control and documentation of parameters
  • Torque Display: Integrated torque trend display for measuring viscosity changes
  • Speed Control: Microprocessor-controlled technology automatically adjusts speed and maintains constant shaft speed
  • Safety Features: Safety circuits for automatic cut-off in anti-stall or overload conditions
  • Functions: Programmable functions, integrated temperature measurement, interval operation, timer function, adjustable safety circuit, locked function, infinitely adjustable speed, overload protection, and short-term overload operation

This IKA EUROSTAR 200 Control S 2 overhead stirrer is suitable for laboratories requiring powerful, precise, and safe stirring performance for highly viscous samples.

Downloads

Accessories

H-stand R 2722 for overhead stirrers and Disperser T 50 digital ULTRA-TURRAX®

ProductTypeDepthMfr#Part#AvailabilityPrice
R 2722420 mm00014120009.224 026In stock₹165,034.80

Bosshead R 271 for overhead stirrers and Disperser T 50 digital ULTRA-TURRAX®

ProductTypeUNSPSCMfr#Part#AvailabilityPrice
R 2714112241300026640009.224 266In stock₹66,668.82

Compare similar models

Overhead stirrer EUROSTAR 200 control S 2 0/6 - 2.000 min-1, w/o accessories with UK plug
Available soon
IKA Overhead Stirrer EUROSTAR 200 Control S 2, 0/6 - 2,000 min-1

₹901,142.40

Inc. GST

Manufacturer P/N

0003992002

Part Number

9.816 719

Manufacturer

IKA

Plug type

UK

Overhead stirrer EUROSTAR 200 control 0/6 - 2.000 min-1, w/o accessories

Manufacturer P/N

0003992000

Part Number

9.816 718

Manufacturer

IKA

Plug type

EU

Rührwerk EUROSTAR 200 control S 3 0/6 - 2.000 min-1, w/o accessories with Swiss plug

Manufacturer P/N

0003992003

Part Number

9.816 720

Manufacturer

IKA

Plug type

CH

Frequently asked questions

It is an extremely powerful laboratory stirrer designed for highly viscous applications and quantities up to 100 l (H2O). It features a removable wireless controller, digital TFT display, automatic speed adjustment, and constant speed control even when sample viscosity changes.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story