Representative Image

Kern & Sohn Ultrasonic Material Thickness Gauge - External for TN-GOLD, d = 0.01 mm (7 MHz)

Max. measured value

Measured range

Min. measured value

Resolution

Specifications

Compare models
HS Code #
90278990
Battery/ rechargeable battery
2 x 1.5 V, AA
Depth
74 mm
Designation ANSI
AA
Dimensions (WxDxH)
150 x 74 x 32 mm
Height
32 mm
Max. measured value
80 mm
Max. voltage battery/ rechargeable battery
1.5 V
Measured range
0.75 ... 80 mm
Min. measured value
0.75 mm
No. of batteries/ rechargeable batteries
2

₹154,163.46

Inc. GST

Available soon

Product description

The Kern & Sohn Ultrasonic Material Thickness Gauge - External for TN-GOLD offers precise, non-destructive thickness measurements with a resolution of 0.01 mm at 7 MHz. This external probe is engineered for high-performance applications where accuracy and reliability are essential. Designed specifically for use with the TN-GOLD series, it ensures consistent and dependable measurements across various material types.

Key Features:

  • Brand: Kern & Sohn
  • Measurement Range: d = 0.01 mm for high-resolution readings
  • Frequency: 7 MHz for accurate ultrasonic signal transmission
  • Compatibility: Designed for use with TN-GOLD series thickness gauges
  • Application: Ideal for precision material thickness evaluation in industrial and laboratory environments
  • Scan mode: 10 measurements per second or single point measuring mode
  • Program Memory: Internal memory for up to 20 files, each storing up to 100 values
  • Selectable measuring units: mm, inch
  • Power Supply: Battery operation
  • Connectivity: USB data interface standard (for models with 0.01 mm readout)

Scope of Supply:

  • Ultrasonic thickness gauge
  • External sensor
  • Carrying case

This ultrasonic thickness gauge accessory is a vital tool for quality assurance, inspection, and material testing professionals.

Downloads

Compare similar models

Ultrasonic material thickness gauge - external for TN-GOLD - , d= 0.01 mm (7 MHz)

Manufacturer P/N

TN 80-0.01US

Part Number

4.691 209

Manufacturer

KERN & SOHN

Max. measured value

80 mm

Ultrasonic material thickness meter TN 230-0.1US 230 mm / 0.1 mm

Manufacturer P/N

TN 230-0.1US

Part Number

6.270 973

Manufacturer

KERN & SOHN

Max. measured value

230 mm

Ultrasonic material thickness meter TN 80-0.1US 80 mm/ 0.1 mm

Manufacturer P/N

TN 80-0.1US

Part Number

6.270 972

Manufacturer

KERN & SOHN

Max. measured value

80 mm

Ultrasonic material thickness gauge TN 300-0.01US - external -, d= 0.01 mm (2.5 MHz)

Manufacturer P/N

TN 300-0.01US

Part Number

4.691 208

Manufacturer

KERN & SOHN

Max. measured value

300 mm

Ultrasonic material thickness gauge - external - , d= 0.01 mm (5 MHz)

Manufacturer P/N

TN 230-0.01US

Part Number

4.691 207

Manufacturer

KERN & SOHN

Max. measured value

230 mm

Frequently asked questions

It offers precise, non-destructive thickness measurements with a resolution of 0.01 mm at 7 MHz. This external probe is engineered for high-performance applications where accuracy and reliability are essential. Designed specifically for use with the TN-GOLD series, it ensures consistent and dependable measurements across various material types.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story