Representative Image

Ludwig Schneider Bottle Thermometer F-010-1S, -30...+0°C:0.5°C Red Spirit Filled, for Refrigerators with DAkkS Calibration with 3 Test Points

Accuracy

Checkpoints

Division

Length

Max. temperature

Min. temperature

Temperature

Specifications

Compare models
HS Code #
90251180
Accuracy
±1 °C
Accuracy
1 °C
Checkpoints
3
Description
Ethylene glycol
Division
0.5 °C
Length
130 mm
Max. temperature
0 °C
Min. temperature
-30 °C
Temperature
-30 ... 0 °C
UNSPSC
41112200

₹78,195.06

Inc. GST

Available soon

Product description

The Ludwig Schneider Bottle Thermometer F-010-1S is a high-precision thermometer designed for use in refrigerators. With a measurement range of -30°C to +0°C and a precision of 0.5°C, it ensures accurate temperature readings. The thermometer is filled with red spirit and comes with DAkkS calibration, providing traceable accuracy for laboratory and industrial applications. It includes three test points, allowing for reliable calibration and verification.

Key Features:

  • Brand: Ludwig Schneider
  • Measurement Range: -30°C to +0°C
  • Accuracy: 0.5°C
  • Filling: Red spirit-filled
  • Calibration: DAkkS calibration with three test points for verified accuracy
  • Application: Ideal for use in refrigerators and other controlled environments
  • Packaging: Sold individually

The Ludwig Schneider Bottle Thermometer F-010-1S is an essential tool for laboratories and industries requiring precise temperature control and calibration.

Compare similar models

Bottle thermometer F-010-1S, -30...+0°C:0.5°C red spirit filled, for refrigerators with DAkks calibration with 3 test points

Manufacturer P/N

8000112/04/3P

Part Number

6.286 997

Manufacturer

Ludwig Schneider

Accuracy

±1 °C

Bottle thermometer F-010-1S, -30...+0:0.5°C with red filling, length 130mm, for freezers, incl. DAkks-calibration with 1 TP

Manufacturer P/N

7000112/04/1P

Part Number

6.289 400

Manufacturer

Ludwig Schneider

Accuracy

±1 °C

Bottle thermometer F-100-01S, -25...-5:0.1°C with blue filling, length 210mm, for freezers, incl. DAkkS- Calibration with 2 Testpoints

Manufacturer P/N

8010111/04/2P

Part Number

6.289 841

Manufacturer

Ludwig Schneider

Accuracy

±0.2 °C

Bottle thermometer R-200-01S, -2...+10:0.1°C with blue filling, length 230mm, for freezers incl. DAkkS calibration with 3 test points

Manufacturer P/N

8010112/04/3P

Part Number

6.286 998

Manufacturer

Ludwig Schneider

Accuracy

±0.2 °C

Bottle thermometer R-200-01S For freezers -2...+10:0,1°C With blue filling, length 230mm,

Manufacturer P/N

7010112/04/1P

Part Number

6.289 401

Manufacturer

Ludwig Schneider

Accuracy

±0.2 °C

Bottle thermometer R-200-01S, -2...+10:0.1°C with blue filling, length 230mm, for freezers incl. DAkkS calibration with 2 test points

Manufacturer P/N

8010112/04/2P

Part Number

6.286 107

Manufacturer

Ludwig Schneider

Accuracy

±0.2 °C

Frequently asked questions

It is a high-precision thermometer designed for use in refrigerators. With a measurement range of -30°C to +0°C and a precision of 0.5°C, it ensures accurate temperature readings. The thermometer is filled with red spirit and comes with DAkkS calibration, providing traceable accuracy for laboratory and industrial applications. It includes three test points, allowing for reliable calibration and verification.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story