Representative Image

Macherey-Nagel EC HPLC Column EC 100/2 NUCLEODUR PFAS, 3 µm Length 100 mm, ID 2 mm

Specifications

Eluent in column
Acetonitrile/water
Endcapped
Yes
Int. Ø
2 mm
Length
100 mm
Material column
Stainless steel
Max. temp. resistance
60 °C
Method
Analytical
Particle size
3 µm
Particle type
Fully porous
pH stability
1 ... 9

₹195,029.22

Inc. GST

Available soon

Product description

The Macherey EC HPLC Column EC 100/2 NUCLEODUR PFAS, 3 µm, Length 100 mm, Internal Diameter 2 mm is designed for specialised PFAS analysis using a hydrophobic reversed phase with distinct polar selectivity. Made from high purity NUCLEODUR HPLC silica gel and extensively endcapped, this column supports sensitive LC/MS analysis with low bleeding characteristics.

Key Features:

  • Brand: Macherey
  • Column Type: EC HPLC column
  • Model: EC 100/2 NUCLEODUR PFAS
  • Particle Size: 3 µm
  • Length: 100 mm
  • Internal Diameter: 2 mm
  • Phase: Hydrophobic reversed phase with distinct polar selectivity
  • Material: High purity NUCLEODUR HPLC silica gel
  • Design: Extensively endcapped with low bleeding characteristics
  • Application: Suitable for specialised PFAS analysis and high sensitivity LC/MS analysis

This NUCLEODUR PFAS EC HPLC column is suitable for laboratories requiring dependable chromatographic performance for targeted PFAS analysis and sensitive LC/MS workflows.

Frequently asked questions

The EC 100/2 NUCLEODUR PFAS is designed for specialised PFAS analysis and high sensitivity LC/MS analysis. The stated format and features make the product suitable for routine laboratory work within that application.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

₹195,029.22

Inc. GST