Representative Image

Vacuubrand Chemistry Diaphragm Pump ME 4C NT, One-Stage, 230 V / 50 Hz, CEE Plug

Plug type

Specifications

Compare models
Depth
254 mm
Dimensions (WxDxH)
243 x 254 x 198 mm
Flow rate
3.9 m³/h
Height
198 mm
No. of stages
1
Plug type
EU
Type
ME 4C NT
Ultimate vacuum
70 mbar
UNSPSC
40151502
Width
243 mm

Alternative in-stock items

₹428,566.56

Inc. GST

Available soon

Product description

The Vacuubrand ME 4C NT is a high-performance, one-stage diaphragm pump designed for laboratory applications requiring efficient and reliable vacuum generation. Operating at 230 V with a frequency of 50 Hz, this pump is equipped with a CEE plug for easy connection. It is ideal for chemical processing, sample handling, and other laboratory tasks that demand precise vacuum control.

Key Features:

  • Brand: Vacuubrand
  • Type: One-stage diaphragm pump for high-performance vacuum generation
  • Voltage: 230 V
  • Frequency: 50 Hz
  • Plug Type: CEE plug for easy mains connection
  • Ultimate Vacuum: 70 mbar (52 torr)
  • Flow Rate: 3.9 m³/h (2.6 cfm) at 50 Hz
  • Number of Heads: 2
  • Number of Stages: 1
  • Rated Motor Power: 0.18 kW
  • Inlet/Outlet Connection: Hose nozzle DN 8-10 mm
  • Operating Temperature Range: 10°C to 40°C
  • Storage Temperature Range: -10°C to 60°C

This diaphragm pump is an essential tool for laboratories that require a dependable, efficient vacuum pump for a wide range of chemical and sample processing applications.

Downloads

Accessories

Sealing kit NT for chemistry diaphragm pumps NT

ProductForUNSPSCMfr#Part#AvailabilityPrice
MZ 2C NT40151502206968696.241 476₹60,643.74
MD 4C NT40151502206968706.239 489₹115,655.34
ME 4 NT, MZ 2 NT40151502206968609.880 902₹30,518.34
ME 4C NT40151502206968649.880 906₹35,233.62
MZ 2D NT40151502206968639.880 904₹30,518.34
MV 2 NT / MD 4 NT40151502206968619.880 905₹58,548.06
ME 8 NT40151502206968629.880 903₹48,331.62
ME 8C NT40151502206968679.880 907₹68,502.54

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081₹16,503.48
PVC34.9 mm206860634.714 084₹45,450.06
PVC38.1 mm206860654.714 085₹53,046.90
PVC15.9 mm206860614.714 082₹19,254.06
PVC22.3 mm206860624.714 083₹23,052.48

Compare similar models

Chemistry diaphragm pump ME 4C NT one-stage, 230 V~ 50 Hz plug CEE

Manufacturer P/N

20731200

Part Number

9.880 894

Manufacturer

VACUUBRAND​

Plug type

EU

Chemistry diaphragm pump ME 4C NT one-stage, 230 V~ 50 Hz plug CH

Manufacturer P/N

20731201

Part Number

9.880 895

Manufacturer

VACUUBRAND​

Plug type

CH

Chemistry diaphragm pump ME 4C NT, one stage, certification (NRTL): C/US230 V / 50-60 Hz, UK/IN mains cable

Manufacturer P/N

20731202

Part Number

4.670 425

Manufacturer

VACUUBRAND​

Plug type

UK

Chemistry diaphragm pump ME 4C NT, one stage, certification: (NRTL): C/US100-115 V / 50-60 Hz, 120 V / 60 Hz, US mains cable

Manufacturer P/N

20731203

Part Number

4.670 426

Manufacturer

VACUUBRAND​

Plug type

US

More items to explore

Diaphragm pumps chemistry design, ME 1C

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUME 1C207211009.880 934In stock₹185,467.68
UKME 1C207211029.880 936₹185,467.68
CHME 1C207211019.880 935₹185,467.68
USME 1C207211039.880 937₹185,467.68

Frequently asked questions

It is a high-performance, one-stage diaphragm pump designed for laboratory applications requiring efficient and reliable vacuum generation. Operating at 230 V with a frequency of 50 Hz, this pump is equipped with a CEE plug for easy connection. It is ideal for chemical processing, sample handling, and other laboratory tasks that demand precise vacuum control.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

₹428,566.56

Inc. GST

Vacuubrand Chemistry Diaphragm Pump ME 4C NT, One-Stage, 230 V / 50 Hz, CEE Plug | LabFriend India