Vacuubrand Chemistry Membrane Pump MV 10C NT +EK, Four-Stage, 200–230 V / 50–60 Hz, with CEE Mains Cable

Plug type

Specifications

Compare models
HS Code #
84141089
Depth
387 mm
Dimensions (WxDxH)
528 x 387 x 395 mm
Flow rate
9.5 m³/h
Height
395 mm
Plug type
EU
Type
MV 10C NT + EK
Ultimate vacuum
0.9 mbar
Ultimate vacuum with gas ballast
1.5 mbar
UNSPSC
40151502
Width
528 mm

Alternative in-stock items

₹1,939,551.84

Inc. GST

Available soon

Product description

The Vacuubrand MV 10C NT +EK is a high-performance, four-stage diaphragm pump designed for continuous, oil-free pumping of corrosive gases and vapors in laboratory settings. Operating at 200–230 V with a frequency of 50–60 Hz, this pump comes equipped with a CEE mains cable for convenient integration into your laboratory infrastructure.

Key Features:

  • Brand: Vacuubrand
  • Type: Four-stage diaphragm pump for high-performance vacuum generation
  • Voltage: 200–230 V
  • Frequency: 50–60 Hz
  • Plug Type: CEE mains cable for easy connection
  • Ultimate Vacuum: 0.9 mbar (0.68 torr)
  • Ultimate Vacuum with Gas Ballast: 1.5 mbar (1.1 torr)
  • Max. Pumping Speed at 50 Hz: 9.5 m³/h
  • Max. Pumping Speed at 60 Hz: 5.6 cfm
  • Number of Heads: 8
  • Number of Stages: 4
  • Inlet Connection: Small flange KF DN 25
  • Outlet Connection: Hose nozzle DN 8–10 mm
  • Coolant Connection: 2 x hose nozzle DN 6–8 mm
  • Rated Motor Power: 0.53 kW
  • Rated Motor Speed at 50/60 Hz: 1650 min⁻¹
  • Protection Class (IEC 60529): IP 40
  • Dimensions (L x W x H): 528 mm x 387 mm x 395 mm
  • Weight: 28.3 kg
  • Noise Level: 50 dBA
  • ATEX Conformity: II 3/- G Ex h IIC T3 Gc X (Internal Atm. only)

Note: An End User Declaration form must be completed after placing the order for this item.

This diaphragm pump is an essential tool for laboratories that require a dependable, efficient vacuum pump for a wide range of chemical and sample processing applications. Its robust construction and high chemical resistance make it suitable for demanding environments. The included exhaust waste vapor condenser (EK) enables near-complete solvent recovery, efficient recycling, and active protection of the environment.

Downloads

Accessories

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081₹16,503.48
PVC34.9 mm206860634.714 084₹45,450.06
PVC38.1 mm206860654.714 085₹53,046.90
PVC15.9 mm206860614.714 082₹19,254.06
PVC22.3 mm206860624.714 083₹23,052.48

Compare similar models

Chemistry membrane pump MV 10C NT +EK four-step,200-230 V, 50-60 Hz with CEE mains cable   2B350i

Manufacturer P/N

20744500

Part Number

9.880 976

Manufacturer

VACUUBRAND​

Plug type

EU

Chemical vacuum system MV 10C NT +EK 100-115 V/50-60 Hz, US plug 2B350i

Manufacturer P/N

20744503

Part Number

4.701 130

Manufacturer

VACUUBRAND​

Plug type

US

More items to explore

Diaphragm pumps chemistry design, ME 1C

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUME 1C207211009.880 934In stock₹185,467.68
UKME 1C207211029.880 936₹185,467.68
CHME 1C207211019.880 935₹185,467.68
USME 1C207211039.880 937₹185,467.68

Frequently asked questions

It is a high-performance, four-stage diaphragm pump designed for continuous, oil-free pumping of corrosive gases and vapors in laboratory settings. Operating at 200–230 V with a frequency of 50–60 Hz, this pump comes equipped with a CEE mains cable for convenient integration into your laboratory infrastructure.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story