Representative Image

Bohlender b.safe Waste Cap B63 3x UNF1/4", 1x GL14, 1x NPT1/8"

Brand:Bohlender

Capillary connections

No. of blind plugs

No. of fittings

No. of olives

Specifications

Compare models
Capillary connections
3
Connection for exhaust filter
1
Hose connections
1
Material
PE
No. of blind plugs
2
No. of fittings
3 x 1,6/ 2,2/ 3,2 mm
No. of olives
1
Thread
B 63
UNSPSC
41115700

₹45,450.06

Inc. GST

Available soon

Product description

The Bohlender b.safe Waste Cap B63 3x UNF1/4", 1x GL14, 1x NPT1/8" is a reliable and chemically resistant cap designed for safe solvent waste disposal in laboratory environments. It features a freely movable PTFE insert for secure sealing and reliable connections. The cap supports three UNF1/4" fittings suitable for capillaries with outer diameters of 1.6, 2.2, and 3.2 mm, one GL14 thread compatible with b.safe exhaust air filters (filter not included), and one NPT1/8" hose connection for tubing with inner diameters of 5.5 to 8 mm. This design ensures flexible integration and prevents solvent vapor escape, enhancing laboratory safety.

Key Features:

  • Brand: Bohlender
  • Material: Durable PE construction with a free movable PTFE insert
  • Connections: 3x UNF1/4" fittings (for capillaries O.D. 1.6/2.2/3.2 mm), 1x GL14 thread, 1x NPT1/8" hose connection (for tubing I.D. 5.5 to 8 mm)
  • Includes: Fittings, blind fittings, hose olive
  • Application: Ideal for solvent waste management systems in laboratories

Scope of Supply:

  • Fittings (UNF 1/4")
  • Blind fittings (UNF 1/4")
  • Hose olive (NPT 1/8")

This waste cap ensures lab safety by preventing solvent vapor escape and enabling organized solvent waste handling with precision fittings.

Downloads

Accessories

Exhaust Filter, PP

ProductMaterialFilter sizeMfr#Part#AvailabilityPrice
PPSM 506-016.313 839In stock₹23,838.36
PPMM 506-026.313 840In stock₹37,460.28
PPLM 506-036.313 841In stock₹47,938.68

Hose connectors for Waste Caps

ProductMaterialLengthMfr#Part#AvailabilityPrice
PP45 mmM 503-014.681 618₹3,667.44
PTFE45 mmM 503-054.681 619₹7,072.92
PP30 mmM 503-084.681 620₹3,405.48
PP32 mmM 503-094.681 621₹3,012.54
PP23 mmM 503-104.681 622₹3,012.54
PP26 mmM 503-114.681 623₹3,012.54
PP26 mmM 503-124.681 624₹3,012.54
PP30 mmM 503-134.681 625₹3,012.54
PP36 mmM 503-144.681 626₹3,012.54
PTFE45 mmM 503-154.681 627₹7,334.88
PP40 mmM 503-164.681 628₹3,012.54
PP48 mmM 513-014.681 643₹3,012.54
PP41 mmM 513-024.681 644₹3,012.54
PP30 mmM 518-014.681 647₹3,274.50

Compare similar models

b.safe Waste Cap B63 3x UNF1/4", 1x GL14, 1x NPT1/8"

Manufacturer P/N

M 363-30

Part Number

4.681 603

Manufacturer

Bohlender

Capillary connections

3

b.safe Waste Cap B63 3x UNF1/4", 1x GL14
Available soon
Bohlender b.safe Waste Cap B63 3x UNF1/4", 1x GL14

₹54,094.74

Inc. GST

Manufacturer P/N

M 363-01

Part Number

4.681 601

Manufacturer

Bohlender

Capillary connections

3

b.safe Waste Cap B63 2x UNF1/4", 1x GL14, 1x NPT1/8"

Manufacturer P/N

M 363-03

Part Number

4.681 602

Manufacturer

Bohlender

Capillary connections

2

Frequently asked questions

It is a reliable and chemically resistant cap designed for safe solvent waste disposal in laboratory environments. It features a freely movable PTFE insert for secure sealing and reliable connections. The cap supports three UNF1/4" fittings suitable for capillaries with outer diameters of 1.6, 2.2, and 3.2 mm, one GL14 thread compatible with b.safe exhaust air filters (filter not included), and one NPT1/8" hose connection for tubing with inner diameters of 5.5 to 8 mm. This design ensures flexible integration and prevents solvent vapor escape, enhancing laboratory safety.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

₹45,450.06

Inc. GST