Representative Image

Lenz-Laborglas Chromatography Column with Frit, NS Socket and PTFE Stopcock, 600 mm Length, 30 mm Diameter

Ø

Dimensions (ØxL)

Length

Nominal capacity

Socket[s]

Specifications

Compare models
Ø
30 mm
Dimensions (ØxL)
30 x 600 mm
Length
600 mm
Material
DURAN® tubing
Material stopcock
PTFE key
Nominal capacity
430 ml
Socket[s]
NS 29/32
UNSPSC
41115711
With stopcock
Yes

₹26,981.88

Inc. GST

Available soon

Product description

The Lenz-Laborglas Chromatography Column with Frit, NS Socket and PTFE Stopcock, 600 mm Length, 30 mm Diameter is designed for reliable laboratory separation and purification applications. Manufactured from DURAN® glass tubing, the column features an integrated sintered glass frit with porosity 0 and a PTFE stopcock for controlled liquid flow.

Key Features:

  • Brand: Lenz-Laborglas
  • Product Type: Laboratory chromatography column
  • Column Length: 600 mm
  • Column Diameter: 30 mm
  • Material: Manufactured from DURAN® glass tubing
  • Frit: Integrated sintered glass frit
  • Frit Porosity: Porosity 0
  • Connection: NS socket for connection to compatible laboratory apparatus
  • Stopcock: PTFE stopcock for controlled flow and chemical resistance
  • Applications: Suitable for laboratory chromatography, separation and purification procedures

This Lenz-Laborglas Chromatography Column is ideal for laboratories requiring a durable DURAN® glass column with an integrated porosity 0 frit and PTFE stopcock for controlled chromatographic separations.

Downloads

Compare similar models

Chromatographic Columns with Frit, PTFE- or Valve Stopcock, Length mm 600 Column D.mm 30

Manufacturer P/N

05450706

Part Number

6.303 297

Manufacturer

Lenz-Laborglas

Ø

30 mm

Chromatographic Columns with Frit, PTFE- or Valve Stopcock, Length mm 400 Column D.mm 20

Manufacturer P/N

05450704

Part Number

6.203 961

Manufacturer

Lenz-Laborglas

Ø

20 mm

Chromatographic Columns with Frit, PTFE- or Valve Stopcock, Length mm 200 Column D.mm 15

Manufacturer P/N

05450703

Part Number

9.025 914

Manufacturer

Lenz-Laborglas

Ø

15 mm

Chromatographic Columns with Frit, PTFE- or Valve Stopcock, Length mm 300 Column D.mm 10

Manufacturer P/N

05450702

Part Number

9.025 913

Manufacturer

Lenz-Laborglas

Ø

10 mm

Chromatographic Columns with Frit, PTFE- or Valve Stopcock, Length mm 100 Column D.mm 10

Manufacturer P/N

05450700

Part Number

6.225 859

Manufacturer

Lenz-Laborglas

Ø

10 mm

Chromatographic Columns with Frit, PTFE- or Valve Stopcock, Length mm 200 Column D.mm 10

Manufacturer P/N

05450701

Part Number

9.025 912

Manufacturer

Lenz-Laborglas

Ø

10 mm

More items to explore

Chromatographic columns, DURAN® tubing

ProductNominal capacityMaterialMfr#Part#AvailabilityPrice
15 mlDURAN® tubing054407019.025 932In stock₹13,490.94
125 mlDURAN® tubing054407049.025 934In stock₹14,407.80
430 mlDURAN® tubing054407069.025 936In stock₹16,503.48
1000 mlDURAN® tubing054407089.025 938₹28,815.60
35 mlDURAN® tubing054407026.235 814₹19,777.98

Frequently asked questions

It is designed for reliable laboratory separation and purification applications. Manufactured from DURAN® glass tubing, the column features an integrated sintered glass frit with porosity 0 and a PTFE stopcock for controlled liquid flow.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

₹26,981.88

Inc. GST