Representative Image

SCAT Universal Waste Hub "JAN" – S60/61 Safety Funnel, 4x 1.6/2.3/3.2 mm OD

Brand:SCAT

Thread

Specifications

Compare models
Capillary connections
4
Connection for exhaust filter
1
Hose connections
3
No. of fittings
4x1,6/2,3/3,2 mm
No. of olives
3
Thread
S 60/61
UNSPSC
41115700

₹88,149.54

Inc. GST

Available soon

Product description

The SCAT Universal Waste Hub "JAN" – S60/61 Safety Funnel is engineered to provide a secure and efficient method for solvent waste disposal in laboratories. Featuring 4 connection ports (1.6/2.3/3.2 mm OD), this funnel ensures a vapor-tight connection to minimize exposure to hazardous chemicals. It is compatible with S60/61-threaded containers and is designed for use in HPLC systems and other waste liquid handling setups.

Key Features:

  • Brand: SCAT
  • Model: Universal Waste Hub "JAN"
  • Connection Ports: 4x 1.6/2.3/3.2 mm OD
  • Thread Type: S60/61
  • Material: Chemical-resistant construction for long-lasting durability
  • Funnel: Hinged lid with sealing ring for secure closure
  • Filtration: Removable sieve for pre-filtering solid particles
  • Ventilation: SafetyWasteCap with integrated exhaust air filter
  • Hose Compatibility: Hose olives (PP) for tubing with inner diameters of 5 to 11.5 mm and capillary connections
  • Application: Safe and odor-free solvent waste disposal from HPLC units and other lab waste sources

Scope of Supply:

  • Safety funnel
  • 3 hose olives (NPT 1/8")
  • 3 blind fittings (NPT 1/8")
  • Fittings: 4 x 1.6 mm, 4 x 2.3 mm, 4 x 3.2 mm
  • 4 x blind fittings (UNF 1/4")
  • 1 x blind fitting GL 14
  • Exhaust filter size M

The SCAT Universal Waste Hub "JAN" S60/61 is a trusted solution for laboratories needing a safe, leak-proof, and multi-line compatible funnel system for solvent waste collection and chemical safety.

Downloads

Compare similar models

Universal Waste Hub "JAN" - S60/61 safety funnel, 4x 1.6/2.3/3.2 mm OD

Manufacturer P/N

320060

Part Number

4.680 946

Manufacturer

SCAT

Thread

S 60/61

Universal Waste Hub "JAN" - GL45 safety funnel, 4x 1.6/2.3/3.2 mm OD

Manufacturer P/N

320045

Part Number

4.680 941

Manufacturer

SCAT

Thread

GL 45

Universal Waste Hub "JAN" - S50 safety funnel, 4x 1.6/2.3/3.2 mm OD

Manufacturer P/N

320050

Part Number

4.680 942

Manufacturer

SCAT

Thread

S 50

Universal Waste Hub "JAN" - S51 safety funnel, 4x 1.6/2.3/3.2 mm OD

Manufacturer P/N

320051

Part Number

4.680 943

Manufacturer

SCAT

Thread

S 51

Universal Waste Hub "JAN" - S70/71 safety funnel, 4x 1,6/2,3/3,2 mm OD

Manufacturer P/N

320070

Part Number

4.680 947

Manufacturer

SCAT

Thread

S 70/71

Universal Waste Hub "JAN" - S90 safety funnel, 4x 1.6/2.3/3.2 mm OD

Manufacturer P/N

320090

Part Number

4.680 939

Manufacturer

SCAT

Thread

S 90

Universal Waste Hub "JAN" - S65 safety funnel, 4x 1,6/2,3/3,2 mm OD

Manufacturer P/N

320065

Part Number

4.680 937

Manufacturer

SCAT

Thread

S 65

Universal Waste Hub "JAN" - S55 safety funnel, 4x 1.6/2.3/3.2 mm OD

Manufacturer P/N

320055

Part Number

4.680 945

Manufacturer

SCAT

Thread

S 55

Universal Waste Hub "JAN" - B63 safety funnel, 4x 1,6/2,3/3,2 mm OD

Manufacturer P/N

320063

Part Number

4.680 936

Manufacturer

SCAT

Thread

B 63

Universal Waste Hub "JAN" - S95 safety funnel, 4x 1.6/2.3/3.2 mm OD

Manufacturer P/N

320095

Part Number

4.680 940

Manufacturer

SCAT

Thread

S 95

Universal Waste Hub "JAN" - B53 safety funnel, 4x 1.6/2.3/3.2 mm OD

Manufacturer P/N

320053

Part Number

4.680 944

Manufacturer

SCAT

Thread

B 53

Universal Waste Hub "JAN" - B83 safety funnel, 4x 1.6/2.3/3.2 mm OD

Manufacturer P/N

320083

Part Number

4.680 938

Manufacturer

SCAT

Thread

B 83

Frequently asked questions

It is engineered to provide a secure and efficient method for solvent waste disposal in laboratories. Featuring 4 connection ports (1.6/2.3/3.2 mm OD), this funnel ensures a vapor-tight connection to minimize exposure to hazardous chemicals. It is compatible with S60/61-threaded containers and is designed for use in HPLC systems and other waste liquid handling setups.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

₹88,149.54

Inc. GST