Thermo Scientific Barnstead Pacific 12 RO, Pure Water System, 12 L/h, 120-240 V, 50/60 Hz

Type

Specifications

Compare models
Depth
330 mm
Dimensions (WxDxH)
372 x 330 x 603 mm
Power supply frequency
50/60 Hz
Height
603 mm
Max. pressure
6 bar
Max. voltage
240 V
Min. pressure
1.5 bar
Min. voltage
90 V
Power supply
90 ... 240 V, 50/60 Hz
Pressure
1.5 ... 6 bar

₹913,847.46

Inc. GST

Available soon

Product description

The Thermo Scientific Barnstead Pacific 12 RO, Pure Water System, 12 L/h, 120-240 V, 50/60 Hz is designed for producing pure water from tap water for routine laboratory applications. Suitable for glassware rinsing, supplying autoclaves, water baths and incubators, and preparing or diluting buffers and reagents, this modular reverse osmosis system supports reliable daily water purification workflows.

Key Features:

  • Brand: Thermo Scientific
  • Model: Barnstead Pacific 12 RO
  • System Type: Reverse osmosis pure water system
  • Production Rate: 12 L/h
  • Power Supply: 120-240 V, 50/60 Hz
  • Design: Space-saving bench or wall-mounted system
  • Operation: Microprocessor control with automatic operation and continual parameter monitoring
  • Display: Large back-lit control panel showing resistivity/conductivity, operating mode and reservoir fill level
  • Documentation: GLP-compliant data storage with RS-232 interface
  • Pretreatment: Two 10 in cartridge filter housings with 5 µm prefilter, activated carbon and hardness stabiliser cartridge
  • Reservoir Requirement: Requires 30 L, 60 L or 100 L polyethylene reservoir for permeate water storage and dispensing
  • Application: Laboratory glassware rinsing, autoclaves, water baths, incubators, buffers and reagents

This pure water system is a practical choice for laboratories requiring dependable reverse osmosis water production with clear monitoring, flexible installation and GLP-compliant documentation.

Accessories

Reservoirs for pure water purification system Barnstead™ Pacific™ TII and RO

ProductNominal capacityØMfr#Part#AvailabilityPrice
30 l380 mm501554959.535 929₹245,718.48
60 l380 mm501555009.535 933₹281,868.96
100 l380 mm501555039.535 937₹561,380.28

Compare similar models

Pure water system Pacific 12 RO RO equipments 12 l/h, 120-240 V / 50/60 Hz

Manufacturer P/N

50132387

Part Number

9.535 533

Manufacturer

Thermo Scientific

Type

Pacific RO 12

Pure water system Pacific 7 RO RO equipment, 7 l/h, 120-240 V / 50/60 Hz

Manufacturer P/N

50132386

Part Number

9.535 532

Manufacturer

Thermo Scientific

Type

Pacific RO 7

Pure water system Pacific 20 RO RO-equipment, 20 l/h, 120-240 V / 50/60 Hz

Manufacturer P/N

50132388

Part Number

9.535 534

Manufacturer

Thermo Scientific

Type

Pacific RO 20

More items to explore

Pure and Ultrapure water purification system Barnstead™ Smart2Pure™, ASTM I and II

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
Smart2Pure 6 UVMains connection501298859.535 866₹1,156,815.36
Smart2Pure 6 UF/UVMains connection501298879.535 867₹1,275,483.24

Ultrapure water purification system Barnstead™ MicroPure™, ASTM I

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
MicroPure UF/UVMains connection501323709.535 825₹1,004,485.62
MicroPure UVMains connection501323739.535 826₹906,381.60
MicroPure UF/UV-STMains connection501323729.535 829₹1,049,542.74
MicroPure UV-STMains connection501323749.535 830₹948,688.14

Frequently asked questions

It is designed for producing pure water from tap water for routine laboratory applications. Suitable for glassware rinsing, supplying autoclaves, water baths and incubators, and preparing or diluting buffers and reagents, this modular reverse osmosis system supports reliable daily water purification workflows.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

₹913,847.46

Inc. GST