Representative Image

Trajan Scientific Capillary Column BPX70, 25 m x 0.32 mm ID Gauge, 0.25 µm

Film thickness

Int. Ø

Length

Specifications

Compare models
Film thickness
0.25 µm
Int. Ø
0.22 mm
Length
25 m
Max. temperature programme
260 °C
Temperature max. isotherm
250 °C
UNSPSC
41115710

₹131,503.92

Inc. GST

Available soon

Product description

The Trajan Scientific Capillary Column BPX70, 25 m x 0.32 mm ID Gauge, 0.25 µm is optimized for high-efficiency gas chromatography, particularly suited for the separation of cis- and trans-fatty acid methyl esters (FAMEs). Utilizing a highly polar BPX70 stationary phase, this column offers excellent reproducibility, thermal stability, and superior peak resolution, making it ideal for analytical laboratories requiring accurate isomer separation.

Key Features:

  • Brand: Trajan Scientific
  • Phase: BPX70 high-polarity stationary phase
  • Dimensions: 25 m length x 0.32 mm internal diameter
  • Film Thickness: 0.25 µm
  • Application: Specially designed for cis-/trans-isomer separation and FAMEs analysis in gas chromatography

This Trajan Scientific BPX70 capillary column provides laboratories with consistent, high-quality results for critical separations requiring precision and reliability.

Compare similar models

Capillary column BPX70 25 m x 0,32 mm ID gauge 0,25 µm

Manufacturer P/N

054602

Part Number

6.227 373

Manufacturer

Trajan Scientific

Film thickness

0.25 µm

Capillary column BPX70 50 m x 0,32 mm ID gauge 0,25 µm

Manufacturer P/N

054603

Part Number

6.205 238

Manufacturer

Trajan Scientific

Film thickness

0.25 µm

Capillary column BPX70 60 m x 0,22 mm ID gauge 0,25 µm

Manufacturer P/N

054613

Part Number

6.205 239

Manufacturer

Trajan Scientific

Film thickness

0.25 µm

Capillary column BPX70 120 m x 0,25 mm ID gauge 0,25 µm

Manufacturer P/N

054624

Part Number

6.206 833

Manufacturer

Trajan Scientific

Film thickness

0.25 µm

Capillary column BPX70 60 m x 0,32 mm ID gauge 0,25 µm

Manufacturer P/N

054617

Part Number

6.205 100

Manufacturer

Trajan Scientific

Film thickness

0.25 µm

Capillary column BPX70 10 m x 0,10 mm ID gauge 0,2 µm

Manufacturer P/N

054600

Part Number

6.205 237

Manufacturer

Trajan Scientific

Film thickness

0.20 µm

Capillary column BPX70 60 m x 0,25 mm ID, film thickness 0,25 µm

Manufacturer P/N

054623

Part Number

7.625 713

Manufacturer

Trajan Scientific

Film thickness

0.25 µm

Capillary column GC BPX70 0,32mm ID x 0,25µm x 25m length

Manufacturer P/N

054606

Part Number

4.682 422

Manufacturer

Trajan Scientific

Film thickness

0.25 µm

Capillary column GC BPX70 0,22mm ID x 0,25µm x 30m length

Manufacturer P/N

054612

Part Number

4.682 423

Manufacturer

Trajan Scientific

Film thickness

0.25 µm

Capillary column GC BPX70 0,32mm ID x 0,25µm x 30m length

Manufacturer P/N

054616

Part Number

4.682 424

Manufacturer

Trajan Scientific

Film thickness

0.25 µm

Capillary column GC BPX70 0,53mm ID x 0,5µm x 30m length

Manufacturer P/N

054620

Part Number

4.682 425

Manufacturer

Trajan Scientific

Film thickness

0.50 µm

Capillary column GC BPX70 0,25mm ID x 0,25µm x 30m length

Manufacturer P/N

054622

Part Number

4.682 426

Manufacturer

Trajan Scientific

Film thickness

0.25 µm

Capillary column BPX70 50 m x 0.32 mm ID gauge 0.25 µm

Manufacturer P/N

054607

Part Number

6.288 501

Manufacturer

Trajan Scientific

Film thickness

0.25 µm

Frequently asked questions

It is optimized for high-efficiency gas chromatography, particularly suited for the separation of cis and trans-fatty acid methyl esters (FAMEs). Utilizing a highly polar BPX70 stationary phase, this column offers excellent reproducibility, thermal stability, and superior peak resolution, making it ideal for analytical laboratories requiring accurate isomer separation.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

₹131,503.92

Inc. GST